Modèle |
Débit (litres/sec) |
Chute nette (mètres) |
Puissance turbine |
Type de génératrice |
Puissance électrique |
FE 19 | 5 | 10 | 300 watts | courant continu 220 V | 240 watts |
FE 14 | 6 | 16 | 600 watts | courant continu 220 V | 500 watts |
FG 9 | 7 | 35 | 1200 watts | monophasé 220 V | 1000 VA |
FE 27 | 9 | 8,5 | 500 watts | courant continu 220 V | 400 watts |
FG 12 | 10 | 50 | 3000 watts | Monophasé 220 V | 3000 VA |
FF 21 | 11 | 15 | 1200 watts | Monophasé 220 V | 1000 VA |
FJ 9 | 11 | 50 | 2800 watts | Monophasé 220 V | 2600 VA |
FE 36 | 14 | 9 | 900 watts | courant continu 220 V | 700 watts |
FF 27 | 16 | 13 | 1500 watts | Monophasé 220 V | 1400 watts |
FH 17 | 18 | 25 | 3400 watts | Monophasé 220 V | 3500 VA |
FJ 12 | 18 | 45 | 5,2 kW | Triphasé 220/380 V | 5,5 kVA |
FL 9 | 23 | 82 | 10,7 kW | Triphasé 220/380 V | 12 kVA |
FE 50 | 23 | 7,5 | 1300 watts | Monophasé 220 V | 1200 VA |
FH 22 | 23 | 22 | 3900 watts | Monophasé 220 V | 3900 VA |
FF 36 | 23 | 24 | 2300 watts | Monophasé 220 V | 2400 VA |
FJ 16 | 25 | 35 | 6,3 kW | Monophasé 220 V | 6,8 kVA |
FL 14 | 35 | 62 | 15 kW | Triphasé 220/380 V | 16 kVA |
FH 30 | 37 | 20 | 5,9 kW | Triphasé 220/380 V | 6,3 kVA |
FJ 20 | 38 | 33 | 10 kW | Triphasé 220/380 V | 10,5 kVA |
FF 50 | 42 | 11 | 3800 watts | Monophasé 220 V | 3900 VA |
FM 15 | 52 | 62 | 25 kW | Triphasé 220/380 V | 26 kVA |
FG 53 | 53 | 12 | 5 kW | Triphasé 220/380 V | 5,3 kVA |
FF 36 | 24 | 12 | 2300 watts | Monophasé 220 V | 2400 VA |
FH 22 | 23 | 22 | 3900 watts | Monophasé 220 V | 4 KVA |
FJ 16 | 25 | 35 | 6,3 kW | Triphasé 220/380 V | 7 kVA |
FJ 26 | 55 | 32 | 14 kW | Triphasé 220/380 V | 15 kVA |
FG 36 | 58 | 22 | 10 kW | Triphasé 220/380 V | 10,8 kVA |
FO 12 | 60 | 100 | 41 kW | Triphasé 220/380 V | 45 kVA |
FL 21 | 65 | 47 | 24 kW | Triphasé 220/380 V | 25 kVA |
FO 16 | 74 | 79 | 43 kW | Triphasé 220/380 V | 47 kVA |
FH 47 | 85 | 20 | 14 kW | Triphasé 220/380 V | 15 kVA |
FM 25 | 98 | 50 | 40 kW | Triphasé 220/380 V | 44 kVA |
FJ 41 | 103 | 26 | 22 kW | Triphasé 220/380 V | 23 kVA |
FO 18 | 108 | 85 | 72 kW | Triphasé 220/380 V | 81 kVA |
FH 68 | 140 | 16 | 17 kW | Triphasé 220/380 V | 18 kVA |
FM 32 | 147 | 57 | 59 kW | Triphasé 220/380 V | 64 kVA |
FO 23 | 157 | 77 | 100 kW | Triphasé 220/380 V | 113 kVA |
FK 53 | 167 | 25 | 33 kW | Triphasé 220/380 V | 36 kVA |
FJ 68 | 210 | 22 | 35 kW | Triphasé 220/380 V | 38 kVA |
FH 87 | 218 | 16 | 26 kW | Triphasé 220/380 V | 28 kVA |
FM 49 | 233 | 36 | 71 kW | Triphasé 220/380 V | 80 kVA |
FM 57 | 320 | 36 | 96 kW | Triphasé 220/380 V | 108 kVA |
FL 88 | 358 | 22 | 58 kW | Triphasé 220/380 V | 63 kVA |
FM 92 | 485 | 26 | 90 kW | Triphasé 220/380 V | 102 kVA |